ORD 2004-23
TOWN OF TROPHY CLUB, TEXAS ORDINANCE NO. 2004-23 AN ORDINANCE OF THE TOWN OF TROPHY CLUB, TEXAS ADOPTING THE 2003 EDITION OF THE INTERNATIONAL RESIDENTIAL CODE AND ADOPTING PROVISIONS AS FOLLOWS: PROVIDING FOR INCORPORATION OF PREMISES; PROVIDING FOR APPLICABILITY; ADOPTING THE 2003 EDITION OF THE INTERNATIONAL RESIDENTIAL CODE FOR ONE, TWO-FAMILY DWELLINGS AND MULTIPLE SINGLE FAMILY DWELLINGS (TOWNHOUSES) NOT MORE THAN THREE STORIES IN HEIGHT WITH A SEPARATE MEANS OF EGRESS; PROVIDING LOCAL AMENDMENTS THERETO, REGULATING THE CONSTRUCTION, ALTERATION, MOVEMENT, ENLARGEMENT, REPLACEMENT, REPAIR, EQUIPMENT, USE AND OCCUPANCY, LOCATION, REMOVAL AND DEMOLITION OF DETACHED ONE -AND TWO-FAMILY DWELLINGS AND MULTIPLE SINGLE FAMILY DWELLINGS (TOWNHOUSES) NOT MORE THAN THREE STORIES IN HEIGHT WITH A SEPARATE MEANS OF EGRESS WITHIN THE TOWN OF TROPHY CLUB; PROVIDING FOR THE ISSUANCE OF PERMITS AND THE COLLECTION OF FEES THEREFORE; PROVIDING FOR A BOARD OF APPEALS; PROVIDING SEVERABILITY; PROVIDING FOR SAVINGS; PROVIDING A PENALTY NOT TO EXCEED THE SUM OF TWO THOUSAND DOLLARS ($2,000.00) FOR EACH OFFENSE AND A SEPARATE OFFENSE SHALL BE DEEMED COMMITTED EACH DAY DURING OR ON WHICH A VIOLATION OCCURS OR CONTINUES; PROVIDING A PUBLICATION CLAUSE; PROVIDING FOR ENGROSSMENT AND ENROLLMENT; AND PROVIDING AN EFFECTIVE DATE. WHEREAS, the Town of Trophy Club, Texas is a general law municipality empowered under the Texas Local Government Code, Section 51.001., to adopt an ordinance or rule that is for the good government of the Town; WHEREAS, Chapter 214 of the Texas Local Government Code provides for the adoption of the International Residential Code (hereinafter "IRC") as a municipal residential building code for the State of Texas and authorizes municipalities to adopt local amendments to the IRC; WHEREAS, the Town adopted the 2000 IRC and local amendments on December 17, 2001 through the passage of Ordinance No. 2001-31; WHEREAS, beginning in the summer of 2003, the North Central Texas Council of Government's, (hereinafter "NCTCOG"), Regional Codes Coordinating Committee, (hereinafter "RCCC") and its four advisory boards conducted 26 open review meetings over a 10 -month period to review the 2003 editions of the International Codes and to develop regional amendments. Their review and recommendations were completed and endorsed by NCTCOG's Executive Board in March 2004. Now NCTCOG encourages jurisdictions in North Central Texas to adopt the 2003 International Residential Code for One -and Two -Family Dwellings along with regional amendments; and WHEREAS, the Town of Trophy Club Building Inspections Officials have reviewed the International Residential Code, 2003 Edition, along with the specific local amendments recommended by the NCTCOG and finds that it is in the best interest of the Town of Trophy Club to adopt those amendments reflected in this Ordinance; and WHEREAS, the Town Council of the Town of Trophy Club, Texas deems it necessary and beneficial to adopt the updated 2003 Edition of the IRC and the local amendments specified in this Ordinance to safeguard the health, property, safety and general welfare of the citizens of the Town of Trophy Club by regulating and controlling the use, occupancy, maintenance, repair, design, construction and quality of materials for residential structures within the Town. NOW, THEREFORE, BE IT ORDAINED BY THE TOWN COUNCIL OF THE TOWN OF TROPHY CLUB, TEXAS: SECTION 1. INCORPORATION CLAUSE That all of the above premises are true and correct and are hereby incorporated in the body of this Ordinance as if fully set forth herein. SECTION 2. APPLICABILITY CLAUSE That certain documents, copies of which are on file in the Building Inspections Department of the Town of Trophy Club, being marked and designated as International Residential Code, 2003 Edition, including Appendix Chapters, as published by the International Code Council, Inc., are hereby adopted as if fully set out herein, along with the local amendments set out herein, as the Residential Building Code of the Town of Trophy Club regulating the construction, alteration, movement, enlargement, replacement, repair, equipment, use and occupancy, location, removal and demolition of one -and two-family dwellings and multiple single family dwellings (townhouses) not more than three stories in height with a separate means of egress within the Town of Trophy Club. SECTION 3. ADOPTION CLAUSE That the Town Council of the Town of Trophy Club, Texas, does hereby adopt the International Residential Code for one -and two-family dwellings and multiple single family dwellings (townhouses) not more than three stories in height with a separate means of egress, 2003 Edition, published by the International Code Council, including local amendments referenced herein, including Appendix Chapters A, B, C, D, E, F, G, H, I and 1 are hereby adopted as the Residential Building Code for the Town of Trophy Club regulating the construction, alteration, movement, enlargement, replacement, repair, equipment, use and occupancy, location, removal and demolition of detached one -and two-family dwellings and multiple single family dwellings (townhouses) within the Town of Trophy Club. SECTION 4. AMENDMENTS TO THE 2003 INTERNATIONAL RESIDENTIAL CODE The following sections, paragraphs and sentences of the 2003 International Residential Code are hereby amended as follows: Standards type is text from the IRC. Underlined type of text inserted.Lined btypedeleted text fm fn the T©r' A. Section R101.1; insert Town name as follows: R101.1 Title. The provisions shall be known as the Residential Code for One -and Two — Family Dwellings of The Town of Trophy Club, Texas, and shall be cited as such as will be referred to herein as "this code". B. **Section R102.4; change to read as follows: R102.4 Referenced Codes and Standards. The codes, when specifically_ adopted, and standards referenced in this code shall be considered part of the requirements of this code to the prescribed extent of each such reference. Whenever amendments have been adopted to the referenced codes and standards each reference to said code and standard shall be considered to reference the amendments as well. Any reference made to NFPA 70 or the ICC Electrical Code shall mean the Electrical Code as adopted. Where differences occur between provisions of this code and referenced codes and standards, the provisions of this code shall apply. Exception: Where enforcement ...(remainder of exception tnzchanged. f ... C. Section R105.2, item #1; change as follows: One-story detached accessory structures, provided the floor area does not exceed 200 120 square feet (18.58 11.15 m2). D. Section R109.1.3; change to read as follows: R109.1.3 Floodplain inspections. For construction permitted in areas prone to flooding as established by Table R301.2(1), upon ... (bulk of section unchanged) ... construction, the building official May &M4 require submission ... [remainder of section iuich.anged]. E. Section 8110 (R110.1 through R110.4); delete. F. Section R112.2.1 & R1112.2.2 delete. G. Section 8202; change definition of "Townhouse" to read as follows: TOWNHOUSE. A single-family dwelling unit constructed in a group of thi:ee ^r ,,,^�n attached units separated by property lines in which each unit extends from foundation to roof and with open space on at least two sides. Section 8202; add definition of "Naturally durable wood" as follows: NATURALLY DURABLE WOOD. The heartwood of the following species with the exception that an occasional piece with corner sapwood is permitted if 90 percent or more of the width of each side on which it occurs is heartwood. Decay Resistant. Redwood, cedars, black locust and black walnut. Termite Resistant. Redwood and Eastern red cedar. H. Table R301.2(1); fill in as follows: GROUND SNOW LOAD WIND SPEED"I (mph) SEISMIC DESIGN CATEGORY" 5 lb/ft' 90 (3-sec-gust)/75 fastest mile A SUBJECT TO DAMAGE FROM Weathering' Frost tine depthb Termite` Bee-ay� moderate G' very heavy WINTER DESIGN ICE SHIELD FLOOD AIR FREEZING MEAN ANNUAL TEMP"�! UNDER- HAZARDS"- INDEXj- TEMP'`' LAYMENT REQUIRED''' 720F No local code 69°F 64.9T For SI: 1 pound per square foot = 0.0479 kN/m.0', 1 mile per hour = 1.609 km/h. a. No revisions. b. No revisions. C. No revisions. d-. The juiisdiefian shall fill in this of the table with deiate to leve " "slight to pai:t 0o cc ss in Figure of b aeeer-Elanee with b whether- there has been ., hist.,, -y of !-Beal ramna=e. b e d. No fitrther revisions € e. No .farther revisions a f. No fit1-ther revisions h - No further revisions i• h. No further revisions i i. No further revisions 'k -j. No fttt then revisions Figure R301.2(7); delete and renumber figures as heeded. t. Section R302.1; add a second exception as follows: Exceptions: 1. Tool and storage sheds, playhouses and similar structures exempted from permits by Section R105.2 are not required to provide wall protection based on location on the lot. Projections beyond the exterior wall shall not extend over the lot line. 2. Ogen metal carport structures may be constructed within zero (0)_feet of the property line without fire -resistive or opening protection when the location of such is approved as required by other adopted ordinances. J. Section R303.3, exception; change to read as follows: Exception: The glazed areas shall not be required where artificial light and a mechanical ventilation system, complying with one of the following, are provided. 1. The minimum ventilation rates shall be 50 cfm (23.6 L/s) for intermittent ventilation or 20 cfm (9.4 L/s) for continuous ventilation. Ventilation air from the space shall be exhausted directly to the outside. 2. Bathrooms that contain only a water closet. lavatory or combination thereof may be ventilated with an approved mechanical recirculg ng_fan or similar device designed to remove odors from the air. Section R303.8; change to read as follows: R303.8 Required Heating. Whefl the wintef design temperature in Table R301.2(1) is belem, 69BF (16'G), e�,er-y Every dwelling unit shall be provided with heating facilities capable of maintaining a minimum room temperature of 68°F (20°C) at a point 3 feet (914 mm) above the floor and 2 feet (610 mm) from exterior walls in all habitable rooms at the design temperature. (Remainder of'section unchangedf K. Section R311.2.2; change to read as follows: R311.2.2 Under stair protection. Enclosed accessible space under stairs shall have walls, under stair surface and any soffits protected on the enclosed side with 5/8 -inch (15.8 mm) fire -rated irteh(12z -.7 nuR) gypsum board or one-hour fire -resistive construction. L. Section R317.1; add a second exception to read as follows: Exceptions: 1. {existing exception unchanged) 2. Two-family dwelling units that are also divided by a property line through -the structure shall be separated as required for townhouses. M. Section R318; delete. N. Sections R319 and R320; change to read as follows: Revise Section R319.1 to read as follows: 8319.1 Location Required. ib D2001.2(7), Protection from decay shall be provided in the following locations Shall require by the use of naturally durable wood or e , wood that is pressure preservatively treated in accordance with AWPA C1, C2, C3, C4, C9, C15, C18, C22, C23, C24, C28, C31, C33, P1, P2, and P3, or dans, resistat c-u8t, efGeElRfS 1-7. No revision. R319.1.1 Field Treatment. Field cut ends, notches and drilled holes of pressure preservatively treated woad shall be retreated in the field in accordance with AWPA M4. Renumber existing sections R319.1.1 (Ground contact) through 8319.1.4 (Wood columns). Section R320.1; change to read as follows: R320.1 Subterranean Termite Control. In areas favorable to termite damage as established by Table R301 2(1), methods of protection shall be by chemical soil treatment, pressure preservatively treated wood in accordance with the AWPA standards listed in Section R319.1, naturally termite -resistant wood or physical barriers (such as metal or plastic termite shields), or any combination of these methods, or provided with other industry accepted methods of termite protection. Exception: When chemicals or other methods of protection are undesirable to the home ownerlbuyer. O. Section R323.1; change to read as follows: R323.1 General. Buildings and structures, when permitted to be constructed in flood hazard areas ... [bulk of section unchanged] ... shall be designed and constructed as required in accordance with the provisions contained in this section or by other local provisions as applicable. P. Section R602.10.5; add the following exception and figure: Exception: Vertical wall segments in the first of one- or first of two-story buildings next to garage openings shall be permitted to have a 6:1 height -to -width ratio (with height being measured from top of header to sill plate) when constructed in accordance with the following provisions. Each panel shall have a length of not less than 16 inches (406 mm) and a height of not more than 10 feet (3048 mm). Each panel shall be sheathed on one face with a single layer of 318 -inch -minimum - thickness (9.5 mm) wood structural panel sheathing nailed with 8d common or galvanized box nails in accordance with Figure R602.10.5(2). The wood structural panel sheathing shall extend up over the solid sawn or glued -laminated header and shall be nailed in accordance with Figure R602.10.5(2). The header shall extend between the inside faces of the first full-length outer studs of each panel. The clear span of the header between the inner studs of each panel shall be not less than six feet (1829 mm) and not more than 18 feet (5486 mm) in length. A strap with an uplift capacity of not less than 1000 pounds (454 kg) shall fasten the header to the side of the inner studs opposite the sheathing. Two anchor bolts shall be installed in accordance with Section R403.1.6, and plate washers shall be a minimum of 2 inches by 2 inches by 3116 inch (51 mm by 51 mm by 4.88 mm) thick and shall be used on each bolt. This exception is only permitted in Seismic Design Categories A -C. Figure R602.10.5(2) GARAGE DOOR BRACED WALL PANEL FOR USE WITH CONTINUOUSLY SHEATHED WALLS EXTENT OF HEADER �i WIDTH BASED ON 13:1 HEIGHT -TO -WIDTH RATIO: E3 FOR 120'HEIGHT,MIN. WIDTH= 20%FOR9El' 'MIN, 2'X1128' NET HEADER + €- N_- 5 id g TO 18 1 MIN. L2) 2K4 FOR A PANEL SPLICE (IF NEEDED), PANEL `I FASTEN TOP PLATE TO HEADER WITH TIN ! Ei ROWS OF 19DSNIkER NAILS AT3" 0. C. TYP. 3+8' MItJ. TH3C1QaESS WOOD 41E. E STRUCTURAL PANEL SHEATHING E•IE i' I. ' I 1000 LB STRAP OPPOSITE SHEATHING }' TYP. SHEATHING TO -FRAMING NAILING IS MN.(2)2A PER FIG URER602.10.5 REQUIRED. FASTEN SHEATHIIAG TO HEADER WITH BID " COMM7N OR GALVANZED BOXNAIfS INO' GRID hAAK { a I� €:i! PATTERN AS SHOWN ANDS" O.C. INALL MN• 2x4 — HEIGHT — I' FRAMING(STUDS, BWCI4NG,AND S11 IS) FRAMING :+N 10 .�� EK TYP. ; E �i WIDTH BASED ON 13:1 HEIGHT -TO -WIDTH RATIO: FOR 120'HEIGHT,MIN. WIDTH= 20%FOR9El' + €- HEIGHT, MIN. WIDTH = 19', ETC. id MIN. L2) 2K4 FOR A PANEL SPLICE (IF NEEDED), PANEL ,• j ! EDGES SHALLBE BLOCI(ED, AND OCCUR WITHINW'OF MD•HEIGHT.ONEROW OF E•IE i' I. TYPICALCORNER DETAIL TYP. SHEATHING TO -FRAMING NAILING IS PER FIG URER602.10.5 REQUIRED. fF Z* BLOCONG IS USED, THE 2XWS ' MUST BE NAILED TOGETHER WITH 318D — SEE SECTION 8403.1.8 SINMRS i I I I 1 L Q. Section R703.7.4.1; add a second paragraph to read as follows: For 3'/4 square feet (0.302 m') of wall area, the following dimensions shall be adhered to: 1. When ties are placed on studs 16 in (407 mm) ox.. they shall be spaced no further apart than 29 in (737 mm) vertically starting approximately 15 in (381 mm) from the foundation. 2. When ties are placed on studs 24 in 610 mm o.c., they shall be sl2accd no further apart than 19 in (483 mm) vertically starting approximately 10 in (254 mm) from the foundation. Add Section 8902.3 to read as follows: R. 8902.3 Minimum Roof CIass. All roof coverings shall be a minimum Class C. All individual replacement shingles or shakes shall be a minimum CIass C. Exception: Non -classified roof coverings shall be permitted on buildings of U occupancies having not more than 120 s .ft. of projected roof area. When exceeding 120 sq.ft. of projected roof area, buildings of Uoccupancies may use non -rated non-combustible coverings. S. Section R907.1; add a sentence to read as follows: All individual replacement shingles or shakes shall coMly with Section R902.3. T. N1101.2.1 Compliance. Compliance with this chapter shall be demonstrated by meeting the r-equiFefits of the app either one of the following: Meeting the requirements of this chapter for buildings with a glazing- area that does not exceed 15 percent of the gross area of exterior walls, or 2. Meeting the requirements of this chanter for buildings with a glazing area that is greater than 15 percent but not exceeding 20 -percent of the gross area of exterior walls and air conditioning equipment rated 12 SEER or higher; 3. Meeting,the requirements of this chapter for buildings with a glazing area that is greater than 20 percent but not exceeding 25 percent of the gross area of exterior walls and air conditioning equipment rated 14 SEER or higher;_or 4. Meeting the requirements of the International Enei v Conservation Code for residential buildings, detached one- and two-family dwellings. {Remainder of section unchanged} Add Section N1101.3.4 to read as follows: N1101.3.4 Exterior Basement or Slab Insulation. When susceptibility to termite damage is classified as "very heavy" according to Table R301.2(l), designs employing basement or slab exterior insulation capable of harboring termites shall not be utilized. U. Section N1102.1; amend as follows: N1102.1 Thermal Performance Criteria. The minimum required insulation R -value or the area -weighted average maximum required fenestration U -factor (other than opaque doors which are governed by Section N1102.1.3) for each element in the building thermal envelope (fenestration, roof/ceiling, opaque wall, floor, slab edge, crawl space wall and basement wall) shall be in accordance with the criteria in Table N1102.1. Detached one -and -two family dwellings with greater than -15-25-percent glazing area; townhouses with greater than 25 -percent glazing area; and an esidefitial building in elinates wTth-heat-ia degreedays; shall determine compliance using the building envelope requirements of Chapters 4 or 5 of the International Energy Conservation Code. V. Replace Table N1102.1 with: a. Crawl space insulation is only required for structures with un -insulated floors. Use of this table is limited to projects where the cathedral ceiling area is limited to one third or less of the total ceiling area. Section N1102.1.6; delete last sentence of exception. Section N1102.2; amend as follows: N1102.2 Maximum Solar Heat Gain Coefficient for Fenestration Products. The area - weighted -average solar heat gain coefficient (SHGC) for glazed fenestration installed in locations with 3,500 or fewer heating degree days shall not exceed 0.40. Exceptions: 1. Any glazing facing within 45 degrees of true north; 2. Any glazing facing within 45 degrees of true south which is shaded along its full width by a -permanent overhang with a projection factor of 0.3 or greater. 3. Any fenestration with permanently attached screens where the screens have a rated shading coefficient of .6 or less. TABLE N1102.1 SIMPLIFIED PRESCRIPTIVE BUILDING ENVELOPE THE, COMPONENT CRITERIA MINIMUM REQUIRED THERMAL PERFORMANCE (U -FACTOR AND R - VALUE) MINIMUM INSULATION R -VALUE [(hr.ft'-.°F)/Btu] MAXIMUM Ceilings Ceiling GLAZING open to Joist/Roof Crawl U -FACTOR Attic Rafter Walls Floors Basement Slab Space [Btu/(hr.ft'`.°F) 1 Space Assembly Walls Perimeter Walls 0.65 R-38 R-22 R-13 R-19 R-0 R-0 R-7" a. Crawl space insulation is only required for structures with un -insulated floors. Use of this table is limited to projects where the cathedral ceiling area is limited to one third or less of the total ceiling area. Section N1102.1.6; delete last sentence of exception. Section N1102.2; amend as follows: N1102.2 Maximum Solar Heat Gain Coefficient for Fenestration Products. The area - weighted -average solar heat gain coefficient (SHGC) for glazed fenestration installed in locations with 3,500 or fewer heating degree days shall not exceed 0.40. Exceptions: 1. Any glazing facing within 45 degrees of true north; 2. Any glazing facing within 45 degrees of true south which is shaded along its full width by a -permanent overhang with a projection factor of 0.3 or greater. 3. Any fenestration with permanently attached screens where the screens have a rated shading coefficient of .6 or less. W. Table N1103.5; amend as follows: Cooling Systems FLUID TEMP RANGE (°F) INSULATION "THICKNESS ineliesb Chilled Water, 40-55 4.5 Refrigerant or Brine Below 40 1.25 {Remainder of table unchanged. } Amend footnote "b" to read as follows: b. For piping lengths in excess of five (5) feet (1,524 mm) exposed to outdoor air, increase thickness by 0.5 inch 13 mm). X. Section M1305.1.3; change to read as follows: M1305.1.3 Appliances in Attics. Attics containing appliances requiring access shall be provided ... [bulk of paragraph unchanged] ... from the opening to the appliance. The passageway shall have continuous unobstructed solid flooring in accordance with Chapter 5 not less than -2 — 30 inches (649 762 mm) wide. A level service space at least 30 inches (762 mm) deep and 30 inches (762 mm) wide shall be present along all sides of the appliance where access is required. The clear access opening dimensions shall be a minimum of 20 inches by 30 inches (508 mm by 762 mm), or larger where such dimensions are not large enough to allow removal of the largest appliance. As a minimum, access to the attics ace shall be -provided by one of the following: 1. A permanent stair. 2. A pull down stair. 3. An access door from an upper floor level. Exception: The passageway and level service space are not required where the appliance is capable of being serviced and removed through the required opening. Section M1305.1.3.1; add a sentence to read as follows: Low volta e wiring of 50 Volts or less shall be installed in a manner to prevent h sical damage. Section M1305.1.4.1; change to read as follows: M1305.1.4.1 Ground clearance. Appliances supported from the ground shall be level and firmly supported on a concrete slab or other approved material extending above the adjoining ground a minimum of 3 inches (76 mm). Appliances suspended from the floor shall have a clearance of not less than 6 inches (152 mm) above the ground. Section M1305.1.4.3; add a sentence to read as follows: Low voltage wiring of 50 Volts or less shall be installed in a manner to prevent physical damage. Y. Section M1307.3.1; delete. Z. Section M1501.2; delete and replace with the following: M1501.2 Exhaust duct size. The minimum diameter of the exhaust duct shall be as recommended by the manufacturer, shall be at least the diameter of the appliance outlet and shall be a minimum nominal size of 4 inches (102 mm) in diameter. The size of duct shall not be reduced along its developed length nor at the point of termination. Section M1501.3; change to read as follows: M1501.3 Length Limitation. The maximum length of a clothes dryer exhaust duct shall not exceed 25 feet (7620 mm) from the dryer location to the wall or roof termination with not more than two bends. When extra bends are installed, the maximum length of the duct shall be reduced 2.5 feet (762 mm) for each 45 -degree (0.79 rad) bend and 5 feet (1524 mm) for each 90 -degree (1.6 rad) bend that occur after the first two bends, measuring in the direction of airflow. The maximum length of the exhaust duct does not include the transition duct. {Exception is unchanged) AA. Section M2005.2; change to read as follows: M2005.2 Prohibited Locations. Fuel -fired water heaters shall not be installed in a room used as a storage closet. Water heaters located in a bedroom or bathroom shall be installed in a sealed enclosure so that combustion air will not be Wwn from the living space. Access to such enclosure may be from the bedroom or bathroom when throuf1h a solid door, weather-stripped in accordance with the exterior door air leakage re uirernents of the International Enetin Conservation Cade and equipped with an approved self-closing device. Direct -vent water heaters are not required to be installed within an enclosure_ BB. Section G2408.3; delete. CC. Section G2412.5; add a second paragraph to read as follows: Both ends of each section of medium pressure gas piping shall identify its operating, as pressure with an approved tag. The tags are to be composed of aluminum or stainless steel and the following wording shall be stamped into the tag: "WARNING 113 to 5 psi gas pressure Do Not Remove" DD. Section G2413.3; add an exception to read as follows: Exception: Corrugated stainless steel tubing (CSST) shall be a minimum of 1/2". EE. Section G2415.6; change to read as follows: G2415.6 (404.6) Piping in Solid Floors. Piping in solid floors shall be laid in channels in the floor and covered in a manner what will allow access to the piping with a minimum amount of damage to the building. Where such piping is subject to exposure to excessive moisture or corrosive substances, the piping shall be protected in an approved manner. As an alternative to installation in channels, the piping shall be installed in accordance with Section G2415.11 (404._11 _a easing of sehedule 40 steel, WFOUght, PVC or- ABS tightlypipe with thaii 2 hoc. X51 znm) beyend the peiRt ..r4 ere th. ri n f,-..,-., the d' ea 17'LZ1T.� I7TGC7'GS J Z o Cr] Section G2415.9; change to read as follows: G2415.9 (404.9) Minimum burial depth. Underground piping systems shall be installed a minimum depth of �? 18 inches (305 458 mm) below grade, eheept as pfavided for See6an-C;2^-415 . FF. Section G2415.9.1; delete. GG. Section G2417.1; change to read as follows: G2417.1 (406.1) General. Prior to acceptance and initial operation, all piping installations shall be inspected and pressure tested to determine that the materials, design, fabrication, and installation practices comply with the requirements of this code. The permit holder shall make the applicable tests prescribed in Sections 2417.1.1 through 2417.7.4 to determine compliance with the provisions of this code. The permit holder shall give reasonable advance notice to the code official when the piping system is rea_Y for testing. The equipment. material, power and labor necessary for the inspections and test shall be furnished by the permit holder and the permit holder shall be responsible for determining that the work will withstand the test pressure prescribed in the following tests. Section G2417.4; change to read as follows: G2417.4 (406.4) Test Pressure Measurement. Test pressure shall be measured with a monometer or with a pressure -measuring device designed and calibrated to read, record, or indicate a pressure loss caused by leakage during the pressure test period. The source of pressure shall be isolated before the pressure tests are made. For tests requiring a pressure of 3 psig, mechanical gauges shall utilize a dial with a minimum diameter of three and one half inches 3 '/z" , a set hand 1110 pound incrementation and pressure range not to exceed G psi for tests requiring a pressure of 3 sig. For tests re airing a pressure of 10 psig, mechanical gauges shall utilize a dial with a minimum diameter of three and one-half inches (3 1/z"), a set hand, a _minimum of 2110 ^pound incrementation and a pressure range not to exceed 20 Rsj. ti. v ri„-o aue -h highestthe br-eater- tha�R five times the test pressure. Section G2417.4.1; change to read as follows: G2417.4.1 (406.4.1) Test Pressure. The test pressure to be used shall be not less than e1:�e and one haif times the pfepesed maKifflufn b pressuve, but not less than 3 3 psig (20 kPa gauge), or at the discretion of the Code Official the Piping and valves may be tested at a pressure of at least six 6 inches 152 mm of mercury, measured with a manometer 01' slope gauge b125 psi - (862 b b , piping the test pfessufe shall not exeeed a value tha� pr-eduees a hoop stfess the g ater_thai cn p nt of the speeified minimum yield stiength of theTipe-. For welded pining, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure (3.48 1cPa) (112 psi) and less than 200 inches of water column pressure (52.2 kPa) (7.5 psi), the test pressure shall not be less than ten (10) pounds per square inch 69.6 kPa). For piping,carrying as ata pressure that exceeds 200 inches of water column (52.2 kPa) (7.5 psi), the test pressure shall be not less than one and one-half times the proposed maximum working pressure. Section G2417.4.2; change to read as follows: G2417.4.2 (406.4.2) Test Duration. The test duration shall be held for a length of time satisfactory to the Code Official, but in no case for benoless than 4s -fifteen (15) minutes. For welded oining. and for piping carrving gas at pressures in excess of fourteen (14) inches water column pressure 3.48 kPa). the test duration shall be held for a length of time satisfactory to the Code Official, but in no case for less than thirty (30) minutes. HH. Add Section G2420.1.4 to read as follows: G2420.1.4 Valves in CSST Installations. Shutoff valves installed with corrugated stainless steel (CSST) ninina systems shall be supported with an approved termination fitting, or equivalent support, suitable for the size of the valves, of adequate strength and duality, and located at intervals so as to prevent or damp out excessive vibration but in no case greater than 12 -inches from the center of the valve. Supports shall be installed so as not to interfere with the free expansion and contraction of the system's piping. fittings,_and valves between anchors. All valves and supports shall be designed and installed so they will not be disengaged by movement of the supporting piping_. II. Section G2421.1; add a second paragraph and exception to read as follows: Access to regulators shall comply with the requirements for access to appliances as specified in Section M1305. Exception: A passageway or level service space is not required when the reffulator is capable of being,serviced and removed through the required attic o ening. JJ. Section G2439.5; add a sentence to read as follows: The size of duct shall not be reduced along its developed length nor at the point of termination. Section G2439.5.1; change to read as follows: G2439.5.1 (614.6.1) Maximum Length. The maximum length of a clothes dryer exhaust duct shall not exceed 25 feet (7620 mm) from the dryer location to the outlet terminal with not more than two bends. When extra bends are installed, the maximum length of the duct shall be reduced 2 1/2 feet (762 mm) for each 45 -degree (0.79 rad) bend and 5 feet (1524 mm) for each 90 -degree (1.6 rad) bend that occur after the first two bends, measuring in the direction of airflow. {Exception is unchanged) KK. Section G2445.2; change to read as follows: G2445.2 (621.2) Prohibited Use. One or more un -vented room heaters shall not be used as the sole source of comfort heating in a dwelling unit. Exception: Existing approved unvented heaters may continue to be used in dwelling units, in accordance with the code provisions in effect when installed, when approved by the Code Official unless an unsafe condition is determined to exist as described in International Friel Gas Code Section 108.7. LL. Section G2448.1.1; change to read as follows: G2448.1.1 (624.1.1) Installation Requirements. The requirements for water heaters relative to access. sizing, relief valves, drain pans and scald protection shall be in accordance with this code. MM. Section P2503.5.1, item 1; add a second paragraph to read as follows: Shower receptors shall be tested for water tightness by filling with water to the level of the rough threshold. The drain shall be plugged in a manner so that both sides of pans shall be subjected to the test at the point where it is clamped to the drain. Section P2503.7.2; change to read as follows: P2503.7.2 Testing. Reduced pressure principle ... [bulk of .section unchanged] ... at the time of installation, immediately after repairs or relocation and at regular intervals as required by applicable state or local provisions least afliiaally. NN. Section P2603.2.1; change to read as follows: P2603.2.1 Protection Against Physical Damage. In concealed locations ... [bulk of section unchanged]... Protective shield plates shall be a minimum of .062 -inch -Chick (1.6 mm) steel; and shall cover the area of the pipe where the member is notched or bored-ai:kd Section P2603.6.1; delete and replace with the following: P2603.6.1 Sewer Depth. Building sewers shall be a minimum of 12 inches 304 mm below grade. 00. Section P2709.1; add an exception to read as follows: Exception: Showers designed to comply with ICC ANSI Al17.1._ PP. Section P2801.6; add an exception as follows: Exception: Elevation of the ig ition source is not required for water heaters that are listed as flammable vapor resistant and for installation without elevation. QQ. Section P2902.4.3; changed to read as follows: P2902.4.3 Lawn Irrigation Systems. The potable water supply system to lawn irrigation systems shall be protected against backflow by an atmospheric -type vacuum breaker, a pressure type vacuum breakera double-check assembly or a reduced pressure principle backflow preventer ... {remainder of section unchanged 1. RR. Table P2904.4.1 & P2904.5; delete "Palybutylene (PB) plastic pipe and tubing". Sections P2904.5.1 and P2904.14; delete reference to "PB "plastic pipe. SS. Section P3005.2.6; changed to read as follows: P3005.2.6 Upper terminal Base of stael. Each horizontal drain shall be provided with a cleanout at its upper terminal Aeeessible eleafieuts shall be pfevided fiear- the base of each vei4iea4 waste or- sail staek. Altematively, sueh eleanouts n+ay--be installed outside the 1- ui thin 3 feet (9-111 ) ef the building . aI4 Exception: Cleanouts may he omitted on a horizontal drain less that five 5 feet 1524 mrn in length unless such line is serving sinks or urinals. TT. Section P3103.1; change to read as follows: P3103.1 Roof Extension. All open vent pipes which extend through a roof shall be terminated at Ieast six 6 inches (152 mm) above the roof of r, -.um ^Y' ;nehes a1• eve the antieipated snew aeeumulatie^, except that ... (reinainder of section 1171changed]. UU. Sections P3105.2; change to read as follows: P3105.2 Fixture Drains. The total fall in a fixture drain due to pipe slope shall not exceed one pipe diameter, nor shall the vent pipe connection to a fixture drain, except for water closets, be below the weir of the trap e pt as pr-evided in Seetieti P X105 3 Section 3105.3 and Figure P3105.3; delete. VV. Section P3111; delete. WW. Section P3112.2; delete and replace with the following: P3112.2 Installation. Trans for island sinks and similar equipment shall be roughed in above the floor and may be vented by extending the vent as high as possible, but not less than the drainboard height and then returning it downward and connecting it to the horizontal sink drain immediately downstream from the vertical fixture drain._ The return vent shall be connected to the horizontal drain through a wye-branch fitting and shall, in addition, be provided with a foot vent taken off the vertical fixture vent by means of a wye-branch immediately, below the floor and extending to the nearest partition and then through the roof to the open air or may be connected to other vents at a point not less than six (6) inches (152 mm) above the flood level rim of the fixtures served. Drainage fittings shall be used on all parts of the vent below the floor level and a minimum sloe of one- quarter 114 inch per foot 20.9 m.m/m back to the drain shall be maintained. The return bend used under the drainboard shall be a one (1) piece fitting or an assembly of a forty- five (45) degree (0.79 radius), a ninety (90) degree (1.6 radius) and a forty-five (45) degree 0.79 radius elbow in the order named. Pipe sizing,shall be as elsewhere required in this Code. The island sink drain, upstream of the return vent, shall serve no other fixtures_. An accessible cleanout shall be installed in the vertical portion of the foot vent. XX. Chapters 33 through 42; delete. Replace with the electrical code as adopted. SECTION 5. BOARD OF APPEALS The Town Council shall appoint five (5) members to the Building Board of Appeals as authorized by the International Residential Code, 2003 Edition, as amended, each to be appointed by a majority of the Town Council for a term of two (2) years; and shall appoint five (5) members to the Fire Board of Appeals as authorized by the Uniform Fire Code, 1997 Edition, each to be appointed by a majority of the Town Council for a term of two (2) years. For purposes of this Ordinances, the I.R.C. and the Uniform Fire Code, the Zoning Board of Adjustment of the Town shall be and is designated as the Building Board of Appeals and the Fire Board of Appeals. SECTION 6. SEVERABILITY CLAUSE If any section, article, paragraph, sentence, clause, phrase or work in this Ordinance, or application thereof to any person or circumstance, is held invalid or unconstitutional by a Court of competent jurisdiction, such holding shall not affect the validity of the remaining portions of the Ordinance, and the Town Council hereby declares it would have passed such remaining portions of the Ordinance despite such invalidity, which remaining portions shall remain in full force and effect. SECTION 7. SAVINGS CLAUSE All rights and remedies of the Town of Trophy Club, Texas, are expressly saved as to any and all violations of the provisions of any other Ordinances of the Town affecting building for one -and two-family dwellings and multiple single family dwellings (townhouses) not more than three stories in height with a separate means of egress, which have secured at the time of the effective date of this Ordinance; and, as to such accrued violations and all pending litigation, both civil and criminal, whether pending in court or not, under such Ordinances same shall not be affected by this Ordinance but may be prosecuted until final disposition by the courts. SECTION S. PENALTY CLAUSE It shall be unlawful for any person to violate any provision of this Ordinance, and any person violating or failing to comply with any provision hereof shall be fined, upon conviction, in an amount not more than Two Thousand Dollars ($2,000.00), and a separate offense shall be deemed committed each day during or on which a violation occurs or continues. SECTION 9. PUBLICATION CLAUSE The Town Secretary of the Town of Trophy Club is hereby directed to publish, the Caption, Penalty and Effective Date of this Ordinance as required by Section 52.011 of the Texas Local Government Code. SECTION 10. ENGROSSMENT AND ENROLLMENT CLAUSE The Town Secretary of the Town of Trophy Club is hereby directed to engross and enroll this Ordinance by copying the exact Caption, Penalty and Effective Date in the minutes of the Town Council and by filing this Ordinance in the ordinance records of the Town. SECTION 11. EFFECTIVE DATE CLAUSE That this Ordinance shall be in full force and effect from and after its date of passage, in accordance with law, and it is so ordained. _ PASSED AND APPROVED by the Town Council o the Tows -of Trophy Club, Texas, this the 30`j' day of August 2004, / ' Effective Date: September 4, 2004 ATTEST: Town SecretOry Town of Trophy Club, Texas APPROVED TO AS FORM: Town Attorney Town of Trophy Club, Texas yor Nn of Trop ly Club, Texas